Currently we are not to market or sell REO II with a battery pack. 

However, we are aware of the showroom request for the REO II to have battery compatibility. We are working on a solution to allow REO II to be battery compatible.  

I've double confirmed with Tony all the information and the latest updates regarding the REO II battery pack update.  

  

This update is close to finishing, once it is we can share this info on retail hub, there is no exact completion date at the moment. On completion, a production period will be provided so you can determine if the sofa has the change or not.  

  

Customer who've purchased REO and wish to upgrade to be battery compatible, they may purchase the update kit (see below). This will require technician installation.  ECN-20210624C Reo & Reogrand battery option (1) (3).pdf 

 

For Reo II pre-ECN change, we are looking at creating an upgrade kit for it, but it is not confirmed.  

  

Hope this clarifies the situation, if there are any further questions, feel free to let me know. 

 Reo II SMC Battery Life

SMC 1800mAh

 

Heavy use: (10 Open/close per day per module)      

Life (Days)

3 modules + 1 Battery             

Less than 1 

2 modules + 1 battery                            

2

1 Module + 1 battery                                

4

Light use: (5 Open/close per day per module)      

 

3 modules + 1 Battery                        

2

2 modules + 1 battery                            

 3

1 Module + 1 battery                                 

7

Estimated stand by (No use of motion)

 

3 modules + 1 Battery                           

4

2 modules + 1 battery                            

  7 

1 Module + 1 battery                              

14

 

 

SMC 6000mAh

 

Heavy use: (10 Open/close per day per module)      

Life (Days)

3 modules + 1 Battery                             

4

2 modules + 1 battery                                  

7

1 Module + 1 battery                                 

14

Light use: (5 Open/close per day per module)      

 

3 modules + 1 Battery                          

7

2 modules + 1 battery                             

10

1 Module + 1 battery                                

21

Estimated stand by (No use of motion)

 

3 modules + 1 Battery                            

  14 

2 modules + 1 battery                           

 21 

1 Module + 1 battery                              

30

Q- Can we provide a customer with a three and a half or four-seater Reo Recliner?  

...